Filter Results By:

Products

Applications

Manufacturers

Showing results: 151 - 165 of 209 items found.

  • 8-Channel ADC Module

    FMC108 - Sundance Multiprocessor Technology Ltd.

    The FMC108 is an eight-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC108 card provides eight A/D 14-bit 250MSPS channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC108 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.

  • Multiple-Input Multiple-Output (MIMO) Sine Test

    Crystal instruments

    EDM Modal Sine Testing includes a dedicated test setup and operation process flow using a single or multiple modal shakers outputting a sine wave to acquire FRF signals. The Source Output type is either Swept sine or Stepped sine. The sweep mode can be linear or logarithmic. The FRF signals of each measurement DOFs with respect to defined reference DOF will be constructed. The output drive level can be defined to run the test under no control strategy, or the response of a control channel can be specified to run the test in a closed loop.

  • Optical Loss Test Set (OLTS)

    MaxTester 940/945 - EXFO Inc.

    First tablet-inspired, multifunction optical loss test set (OLTS) delivering insertion loss, optical return loss and fiber length measurements at two wavelengths in five seconds via fully automated bidirectional FasTesT™ analysis. With its step-by-step reference wizard and intelligent fault diagnosis, the MAX-940/945 provides expert guidance throughout the test process to ensure immediate efficiency by first-time users while removing risk of errors or negative loss—a common source of issues when testing low loss fibers.

  • OPTICAL PHASE NOISE TEST AND MEASUREMENT SYSTEM

    OEwaves, Inc

    OEwaves’ HI-Q® Optical Test Measurement System utilizes a homodyne methodology for automated measurement capable of testing ultra-low phase noise laser sources. The user friendly test system is capable of rapidly measuring laser phase noise and estimating its FWHM linewidth down to < 3 Hz without complex setup or reference lasers normally required to make such a narrow linewidth measurement.

  • FMC-HPC ADC Board

    FMC121 - Sundance Multiprocessor Technology Ltd.

    The FMC121 provides two 16-bit A/D channels up to 1Gsps and two 16-bit D/A channels up to 1.4 Gsps data rate with a 2.8 GSPS update rate. The design is based on Texas Instruments’ ADS54J60 Analog-to-Digital converter and Texas Instruments DAC39J84 Digital-to-Analog converter. The sample clock can be supplied externally through a coaxial connection or supplied by an internal clock source (optionally locked to an external reference) for multi-channel synchronization. An external trigger input is available for timing synchronization. The FMC121 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • Rubidium Frequency Standard

    RFS VXI - Holding Informtest

    *RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.

  • 4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ PCI Express Cards

    DAQe-2500 Series - ADLINK Technology Inc.

    ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.

  • Meter Test & Calibration

    Kongter Test & Measurement Co., Limited

    Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.

  • Phase Noise Testers / Signal Source Analyzers

    7000 Series - Berkeley Nucleonics Corporation

    The 7000 series is an all-in-one integrated solution that offers an indispensable set of low-noise phase measurement functions. Offering both Absolute and Additive(residual) measurement capabilities in one unit at no additional cost, the 7000 series is the most flexible solution on the market. The instrument comprises a two-channel, cross-correlation system with two internal, tunable references sources that also allows measurements with externally sourced references. We offer three platform options for the 7000 Series Phase Noise Testers: the 7070 1 MHz to 7 GHz, the 7300 1 MHz to 26 GHz, 7340 1 MHz to 40 GHz, 7350 1 MHz to 50 GHz, and the 7360 1 MHz to 65 GHz.

  • Low Power Potentiostats

    Bank Elektronik

    Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg

  • RF Calibration Accessories

    Fluke Calibration

    Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.

  • Mid-Range Gas Filter Correlation CO Analyzer​

    Model T300M - Teledyne Advanced Pollution Instrumentation

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.

  • FPGA Mezzanine Card

    FMC165 - Abaco Systems Inc

    The FMC165 provides two 14-bit analog-to-digital (A/D) channels supporting RF sampling at 2.6 GSPS and one 14-bit digital-to-analog (D/A) channel with sampling rates up to 5.2 GSPS (2.6 GSPS direct RF synthesis). The converters are clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users.

  • Reference Transmitter

    81492A - Keysight Technologies

    Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

Get Help